Data Sheet: Sundström SR298


Image
Organic gas filter AX — low boiling point
Description

Organic vapour filter class AX for organic vapours with a boiling point below +65°C. Can also be used as an A2 organic gas filter.

Material

Plastic polypropylene. No metal parts.

Usage

Used against organic gas and vapour with a boiling point lower than +65°C,such as certain solvents. The filter fits into the filter attachment of Sundström's half and full face masks. An SR510 particle filter can be snapped onto the front of the filter.
NOTE: When used as an AX filter, the filter is a single-use only filter which must be discarded after 8 hours' use or sooner, depending on the concentration of the contaminant

Size

— Largest diameter: 106 mm
— Thickness: 48 mm

Weight

145 g

Carbon

The filter contains 145 g of activated carbon.

Adsorption capacity as AX
Test gasConc. (PPM)B'through (min)
Isobutane2,50065–70
Dimethyl ether50070–75
Adsorption capacity as A2
Test gasConc. (PPM)B'through (min)
Carbon tetrachloride5,00060–65
Pressure drop

— At 30 l/min: 25-30 Pa (standards requrement: <100 Pa)
— At 95 l/min: 120-140 Pa (standards requirement: <400 Pa)

Storage

Store at room temperature in clean, dry place. If seal has been broken, store away from contaminants in an air-tight container. Shelf life is 5 years if seal is unbroken. Expiry date printed on filter.