Data Sheet: Disposable battery


Image
Single-use, non-rechargeable
Usage

Battery power for SE-shield respirators. The battery contains nonrechargeable Lithium cells. Ideal for emergency response applications where the respirator is used infrequently but must remain ready for immediate use.

Nominal voltage

15 V DC

Nominal capacity

6.4 Ah

Shelf life

Up to 10 years
NOTE: Lithium cell manufacturer states shelf life of 10 years. In practice, shelf life may vary due to individual cell variations, storage conditions etc. For more information on shelf life, please contact S.E.A.

Storage temperature

Max +30°C recommended. For more sever conditions, please consult S.E.A.

Operating temperature

±0° to +55°C

Weight

400 g

Operating time

Achieves significantly longer operating time than the standard rechargeable battery under standard test conditions.

Protection

Internal non-resettable fuses for short-circuit and overheating protection

Transport

Classified as Dangerous Goods Class 9 under the Australian Dangerous Goods Code. Limitations on transportation apply. Batteries are supplied in packaging suitable for transport and compliant with the ADG Code.

Back to product page